ODOT 611 Testing & Inspection
KEM offers ODOT 611 testing and inspection services. ODOT requires specific testing and verification to ensure that new or repaired drainage systems are watertight, structurally sound, and free from defects that could cause failures such as sinkholes.
Typical ODOT 611 testing and repair procedures include:
- CCTV video inspection of the pipe to assess installation quality
- Identifying issues such as misaligned joints, cracks, or infiltration
- Grouting repairs using packers to seal defective joints
- Air testing of the pipe after repairs to confirm the joint is sealed
- Repeating tests until the installation passes
These steps help verify that pipe joints are tight and the installation will not fail over time.