Southwest Interceptor Sewer System Evaluation, NEORSD

KEM participated in the project team conducting a local sanitary system evaluation study for the Northeast Ohio Regional Sewer District, specifically within the service area of their Southwest Interceptor sewer.

Project Details

Client
Northeast Ohio Regional Sewer District

KEM's responsibilities included sanitary sewer micro monitoring and field investigations to identify issues within the service area. As part of the project, KEM performed flow monitoring at 150 locations and carried out approximately 8,000 linear feet of CCTV inspections, 125,000 linear feet of smoke testing, 16,500 linear feet of dye testing, and general field connectivity investigations as required.

Related Projects

Have a Project in Mind?

Tell us what you're planning

KEM's Mansfield office
Headquarters

Mansfield

52 N. Diamond Street
Mansfield, Ohio 44902
KEM's Elyria office

Elyria

526 E. Broad Street
Elyria, Ohio 44035
KEM's Lorain office

Lorain

5065 Oberlin Avenue
Lorain, Ohio 44053